4-санға «Автоматтандыру және ақпараттық технологиялар», «Азық-түлік инженериясы және биотехнология», сондай-ақ «Химиялық технология» бағыттары бойынша мақалалар қабылдау жабылды.

Приём статей в четвёртый номер по направлениям «Автоматизация и информационные технологии», «Пищевая инженерия и биотехнология», а также «Химическая технология» закрыт.

Submissions for the fourth issue in the fields of Automation and Information Technology, Food Engineering and Biotechnology, as well as Chemical Technology, are now closed.

Preview

Bulletin of Shakarim University. Technical Sciences

Bulletin of Shakarim University. Technical Sciences

Advanced search

ADAPTIVE CUTTING TOOL WEAR COMPENSATION IN CNC MANUFACTURING OF TI-6AL-4V CORTICAL BONE SCREWS

https://doi.org/10.53360/2788-7995-2026-3(23)-36

Abstract

This study addresses the problem of ensuring the dimensional accuracy of cortical bone screws manufactured from Ti-6Al-4V titanium alloy using computer numerical control (CNC) machine tools. The relevance of the research is determined by the stringent quality requirements for medical implants and the need to maintain stable thread-forming conditions under progressive cutting tool wear. The aim of the study is to develop and experimentally validate a method for adaptive compensation of thread-cutting head wear using CNC system capabilities. The research was conducted at the Smart Engineering Competence Center of D. Serikbayev East Kazakhstan Technical University. Experimental specimens were manufactured on a MANURHIN K'MX 726 EVO Swiss-type CNC lathe, while the thread geometry was evaluated using a Mahr MarSurf CD 140 contour measuring system. The experimental program comprised nine machining modes with a maximum accumulated cutting length of 57 m. The results showed that increasing accumulated machining length was associated with systematic changes in thread pitch, profile depth, and flank angles. An empirical linear relationship was obtained to estimate the required compensation offset within the investigated machining-length range. For the maximum investigated operating length, the calculated compensation value reached ΔZ = 0.0509 mm, which closely matched the implemented CNC compensation of 0.050 mm. After applying the calculated correction, the thread pitch deviation was limited to 1.28% relative to the nominal value of 1.25 mm, ensuring stable thread profile geometry without tool replacement. The practical significance of the proposed approach lies in improving the dimensional accuracy of medical implants, extending the effective service life of the thread-cutting head, and reducing manufacturing costs. Future research will focus on automated tool wear monitoring systems and the integration of adaptive compensation algorithms into intelligent digital manufacturing environments.

About the Authors

K. Kombayev
D. Serikbayev East Kazakhstan Technical University
Kazakhstan

Kuаt Kombayev – Candidate of Technical Sciences, Associate Professor, International School of Engineering

 Ust-Kamenogorsk, Kazakhstan



Zh. Mukhametbek
D. Serikbayev East Kazakhstan Technical University
Kazakhstan

Zhaksylyk Mukhametbek – Doctoral student of the Educational Program 8D07102 «Mechanical Engineering» research engineer

 Ust-Kamenogorsk, Kazakhstan



B. N. Azamatov
D. Serikbayev East Kazakhstan Technical University
Kazakhstan

Bagdat Nurlanovich Azamatov – PhD, CEO of the «SciMed»

 Ust-Kamenogorsk, Kazakhstan



D. Kaliyev
D. Serikbayev East Kazakhstan Technical University
Kazakhstan

Daniyar Kaliyev – PhD, Head of Competence Center «Smart Engineering»

Ust-Kamenogorsk, Kazakhstan



R. Gabdyssalyk
D. Serikbayev East Kazakhstan Technical University
Kazakhstan

Riza Gabdyssalyk – PhD, Associate Professor

 Ust-Kamenogorsk, Kazakhstan 



References

1. Biomaterials as implants in the orthopedic field for regenerative medicine: Metal versus synthetic polymers / F.D. Al-Shalawi et al // Polymers. – 2023. – № 15(12). – Р. 2601. https://doi.org/10.3390/polym15122601.

2. Bamford E. Tool wear in turning of titanium alloy Ti–6Al–4V: Challenges and potential solutions for crater wear, diffusion and chip formation / E. Bamford // Master’s thesis, Uppsala University. – 2016.

3. Research of cutting temperature reducing of titanium alloy grade 5 below polymorphic transformation depending on calculation of cutting modes / M. Doudkin et al // International Journal of Mechanical and Production Engineering Research and Development. – 2020. – № 10(2). – Р. 747-758. https://doi.org/10.24247/ijmperdapr202074.

4. Ti based biomaterials, the ultimate choice for orthopaedic implants – A review / M. Geetha et al // Progress in Materials Science. – 2009. – № 54(3). – Р. 397-425. https://doi.org/10.1016/j.pmatsci.2008.06.004.

5. Development of biocompatible coatings for orthopedic joint implants / A.B. Kengesbekov et al // Physical Sciences and Technology. – 2025. – № 12(1-2). – Р. 84-94. https://doi.org/10.26577/phst20251218.

6. Microplasma sprayed tantalum coatings on Ti Grade 5 extra-low interstitials: Investigation of thickness and porosity control / K. Kombayev et al // Coatings. – 2025. – № 15(4). – Р. 464. https://doi.org/10.3390/coatings15040464.

7. The progress in titanium alloys used as biomedical implants: From the view of reactive oxygen species / J. Yang et al // Frontiers in Bioengineering and Biotechnology. – 2022. – № 10. – Р. 1092916. https://doi.org/10.3389/fbioe.2022.1092916.

8. DePuy Synthes. (2021). Small Fragment System: Surgical Technique. DePuy Synthes Companies.

9. International Organization for Standardization. (1991). ISO 5835:1991. Implants for surgery – Metal bone screws with hexagonal drive connection, spherical under-surface of head, asymmetrical thread – Dimensions. ISO.

10. Kumar A. Tool wear prediction using multi-sensor data fusion and attention-based deep learning / A. Kumar, V. Vasu // Production Engineering. – 2025. – № 19. – Р. 455-471. https://doi.org/10.1007/s11740-024-01319-6.

11. Machining accuracy prediction and adaptive compensation method of CNC machine tool under absence of machining process sensing / J. Sun et al // Journal of Intelligent Manufacturing. – 2025. – № 36. – Р. 3923-3940. https://doi.org/10.1007/s10845-024-02403-5.

12. ASTM International. (2026). ASTM F136-26: Standard specification for wrought titanium-6aluminum-4vanadium ELI (extra low interstitial) alloy for surgical implant applications (UNS R56401). ASTM International. https://doi.org/10.1520/F0136-26.


Review

For citations:


Kombayev K., Mukhametbek Zh., Azamatov B.N., Kaliyev D., Gabdyssalyk R. ADAPTIVE CUTTING TOOL WEAR COMPENSATION IN CNC MANUFACTURING OF TI-6AL-4V CORTICAL BONE SCREWS. Bulletin of Shakarim University. Technical Sciences. 2026;(3(23)):378-390. (In Kazakh) https://doi.org/10.53360/2788-7995-2026-3(23)-36

Views: 20

JATS XML


Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 License.


ISSN 2788-7995 (Print)
ISSN 3006-0524 (Online)
X