QUALITY CONTROL PERFORMANCE ANALYSIS WITH THE MACHINE PERFORMANCE CHECK SOFTWARE TO CHECK THE VITALBEAM LINEAR ACCELERATOR

Abstract

The development of irradiation techniques based on medical accelerators requires the development of new and more effective quality control programs that would take into account changes in the designs of accelerators and their output devices. Since quality control is an indispensable process for evaluating the functional characteristics of the accelerator, this work is devoted to the study of the effectiveness of procedures using Machine Performance Check. Test checks are shown along with standard procedures. This analysis revealed the need to use MPC for quality control of linear accelerators. MPC application is used to verify the geometry and beam characteristics of linear accelerators using automated checks based on their kV-MV imaging systems. Radiation therapy using linear accelerators requires extensive knowledge of the positioning accuracy of the multi-petal collimator flaps. In this study, preliminary tests with MPC were analyzed using all the energies of the VitalBeam photon beam.

About the Authors

Zh. Yergozhina
Shakarim University of Semey
Kazakhstan


A. Kassymov
Shakarim University of Semey
Kazakhstan


M. Idinov
Shakarim University of Semey
Kazakhstan


A. Khazhidinova
Shakarim University of Semey
Kazakhstan


References

1. Klein E.E, Hanley J, Bayouth J, Yin F-F, Simon W, Dresser S, et al. Task Group 142 report : quality assurance of medical accelerators // Med Phys. Eng . – 2009. – N 36:4197. – P. 212.

2. Tarutin, I.G. Radiation protection during medical exposure // Instruments and measurement methods. – M:, Higher school. 2005. – 335 p.

3. Klimanov V.A. Dosimetric planning of radiation therapy. Part 3. Radiation therapy with beams with modulated intensity. Irradiation optimization. – Tutorial. M.: MEPhI, 2008. – 176 p.

4. International Electrotechnical Commission Publication 977. Medical electron accelerators in the range 1 MeV-50 MeV-guidelines for functional performance characteristics. 1989.

5. Determination of absorbed dose in a patient irradiated by beams of x- or gamma-rays in radiotherapy procedures. – ICRU Report 24. – 1976.


Review

For citations:


Yergozhina Zh., Kassymov A., Idinov M., Khazhidinova A. QUALITY CONTROL PERFORMANCE ANALYSIS WITH THE MACHINE PERFORMANCE CHECK SOFTWARE TO CHECK THE VITALBEAM LINEAR ACCELERATOR. Bulletin of Shakarim University. Technical Sciences. 2021;(4(4)):31-34.

Views: 189


Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 License.


ISSN 2788-7995 (Print)
ISSN 3006-0524 (Online)
X