REVISITING DURABILITY OF PIPELINES IN POLYURETHANE FOAM INSULATION
Abstract
The article presents the results of the study of heat supply pipeline made of steel with thermal insulation of polyurethane foam in polyethylene sheath, operated in Kazakhstan.
The main objective of the study was to determine the service life of heat pipes with a polymer sheath made of high density polyethylene at temperature up to 150° C based on the methods given in local and foreign standards.
A possible variant of the operating mode of heating networks according to operation temperature schedule of 130/70° C for the city of Karaganda (Kazakhstan) is presented. Conclusions are drawn about increasing the life of pipelines in polyurethane foam thermal insulation with a protective casing of high-density low-pressure polyethylene. The dependence of the choice of starting materials for insulation and a waterproof casing is described. The reliability of heat supply systems which directly depends on the service life of heat pipes is analyzed.
About the Authors
A. KalmagambetovaKazakhstan
T. Bogoyavlenskaya
Kazakhstan
References
1. Bukhin V.E. Heat pipes of polypropylene pipes with factory heat-and-water insulation // Pipelines and Ecology. 2002. − No. 3. − P. 19-24.
2. Bukhin V.E. On projects for laying heating networks and economic aspects of the reconstruction of heat supply systems // Pipelines and Ecology. 2007. − No 1. − P. 17-19.
3. Fallatah G., Dobbs N., Gibson A. Long term creep and stress rupture of aramid fibre // Plastics, Rubber and Composites. 2007. Vol. 36, № 9. − Pp. 403-412.
4. Boros S. Long-term hydrostatic strength and design of thermoplastic piping compounds // Journal of ASTM International. 2011. − Vol. 8, Iss. 9. − Pp. 57-72.
5. SNiP 41-03-2003. Thermal insulation of equipment and pipelines. M., 2004.
6. GOST 30732-2006. Steel pipes and fittings with thermal insulation of polyurethane foam with a protective sheath. M., 2006.
7. DIN EN 253-2009. District heating pipes – Preinsulated bonded pipe systems for directly buried hot water networks – Pipe assembly of steel service pipe, polyurethane thermal insulation and outer casing of polyethylene.
8. DIN EN 448-2009. District heating pipes – Preinsulated bonded pipe systems for directly buried hot water networks – Fitting assemblies of steel service pipes, polyurethane thermal insulation and outer casing of polyethylene.
9. Danielewicz, J., Śniechowska, B., Sayegh, M.A., Fidorów, N., Jouhara, H. Three-dimensional numerical model of heat losses from district heating network pre-insulated pipes buried in the ground. Energy. 2016. Vol.108. Pp. 172-184. DOI:10.1016/J.ENERGY.2015.07.012
Review
For citations:
Kalmagambetova A., Bogoyavlenskaya T. REVISITING DURABILITY OF PIPELINES IN POLYURETHANE FOAM INSULATION. Bulletin of Shakarim University. Technical Sciences. 2020;(3(91)):31-34.